Regarding The Rice Cooker
URANUS RICE COOKER REPAIRED PART -2
Authored by Beh.
In
part one of this report I changed the thermal fuse and the machine starts to
work
And
I start to cook rice to test the rice cooker
but the rice cooker failed again and fuse blow again ! This is possible only due to malfunctioning of thermostat
and fuse blow because of to much
heat even more than 139 degree celsius (more
than breaking point of thermal fuse )
Yes
the thermostat is another suspect but
what is the thermostat?
A thermostat is the component of
a control
system which
regulates the temperature of heating or
cooling system
so that the system's temperature is maintained near a desired setpoint
temperature. The name is derived from the Greek words thermos "hot"
and statos "a standing". The thermostat does this by switching
heating or cooling devices on or off, or regulating
the
heat in the rice cooker and
any other heating machine
In
this rice cooker the thermostat failed to regulate the temperature and thermal
fuse acts as safety component and break the circuit to prevent fire from rice
cooker.
In
this rice cooker a bimetal spring is installed as thermostat
Spring
is inside a metal capsule when the heat exceed more than temperature that is
required for cooking the rice in proper time.
spring bimetal thermostat
By
changing the length of spring pushes a piston and piston turns off the internal
switch of rice cooker by changing the
spring thermostat with a new one rice
cooker start to work again.
Conclusion:
the blowing the fuse at first time was because of the malfunctioning of
thermostat not life span of fuse itself.
0 Comments:
Post a Comment
Subscribe to Post Comments [Atom]
<< Home